  • Introduction
advert
unispa > Web interface > Processes > Output > Type

Type

Enabling this option will change the output to PWM mode. This option is only available if the selected Output peripheral is capable of PWM output (D0 - D8). In that case the output assumes a provided duty cycle when on and a constant LOW state (0V) when off.

[VALUE] of this variable may assume values 0 or False for disabling and 1 or True for enabling this option.

HTTP

The device will accept HTTP requests at the following URLs:

(POST) http://[IPv4]/var_set?param=outtyp_[PROCESS ID]&val=[VALUE]
(GET) http://[IPv4]/var_request?param=outtyp_[PROCESS ID]



POST: http://192.168.1.255/var_set?param=outtyp_1&val=1

will switch the type of the Process #1 output to PWM.

Learn more in HTTP API.

MQTT

This parameter cannot be accessed via MQTT. Learn more in MQTT API.