In this article

  • Introduction
advert
unispa > Web interface > Processes > Output > Invert

Invert

As long as enabled, this option logically inverts the output as follows:

  • non-PWM output - the output now assumes a LOW state (0V) when ON and a HIGH state (3.3V) when OFF.
  • PWM output - the output now assumes a provided duty cycle when ON and a constant HIGH state (3.3V) when OFF.

[VALUE] of this variable may assume values 0 or False for disabling and 1 or True for enabling this option.

HTTP

The device will accept HTTP requests at the following URLs:

(POST) http://[IPv4]/var_set?param=outinv_[PROCESS ID]&val=[VALUE]
(GET) http://[IPv4]/var_request?param=outinv_[PROCESS ID]



POST: http://192.168.1.255/var_set?param=outinv_6&val=1

will invert the output of the Process #6.

Learn more in HTTP API.

MQTT

This parameter cannot be accessed via MQTT. Learn more in MQTT API.